Rubber dam Clamps

Clamps are produced from high-quality stainless steel with perfect shape memory.

All clamps are available in srandard and black versions. Black clamps are more comfortable in work due to their anti-reflective properties

 

Brinker Clamps (tissue retractors):

№ B1
Clamp
(for lower molars)
1 pc.
№ B2
Clamp
(for left-side upper molars)
1 pc.
№ B3
Clamp
(for right-side upper molars)
1 pc.
№ B4
Clamp
(for anteriors (incisors and canines))
1 pc.
№ B4-M
Clamp
(for anteriors (incisors and canines))
1 pc.

Clamp B4-M has thinner edges of the working part than clamp B4, that provides more free space in gingival area for performing more various manipulations

№ B5
Clamp
(Brinker "butterfly" clamp with narrow "jaws" (for V class restorations))
1 pc.
№ B6
Clamp
(Brinker "butterfly" clamp with wide "jaws" (for upper and lower anteriors))
1 pc.

Anterior Clamps:

№ W9
Clamp
(wingless "butterfly" clamp for anteriors)
1 pc.
№ 9
Clamp
(winged "butterfly" clamp for anteriors)
1 pc.
№ 9M
Clamp
(“butterfly” clamp for the anterior group of teeth)
1 pc.
№ 9T
Clamp
(“tiger” "butterfly" clamp for anteriors. Retention teeth along the entire length of the clamp cheeks provide a secure fixation on teeth with an atypical crown shape or when it is severely destroyed
1 pc.
№ 212
Clamp
("butterfly" clamp by Ferrier with the effect of mechanical gingival retraction, for restoration of cervical areas of tooth facial surfaces)
1 pc.
№ 210
Clamp
("butterfly" clamp by Ferrier with the effect of mechanical gingival retraction, for restoration of cervical areas of tooth facial surfaces)
1 pc.

Premolar Clamps:

Symmetrical Design

№ 0
Clamp
(for upper and lower premolars, upper incisors)
1 pc.
№ 00
Clamp
(for upper and lower premolars, lower incisors)
1 pc.
№ W00
Clamp
(for upper and lower premolars and anteriors)
1 pc.
№ 1
Clamp
(for upper and lower canines and premolars)
1 pc.
№ OC
Clamp
(for canines and premolars of the upper and lower jaws)
1 pc.
№ 1T
Clamp
("Tiger" clamp for canines and premolars of the upper and lower jaws, for teeth with a severely decayed or missing crown)
1 pc.
№ W2
Clamp
(wingless clamp with flat horizontal "jaws", for small premolars)
1 pc.
№ 2
Clamp
(winged clamp with flat horizontal "jaws", for small premolars)
1 pc.
№ W2A
Clamp
(wingless clamp with flat horizontal "jaws", analogue of clamp 2 with larger "jaws", for large premolars)
1 pc.
№ 2A
Clamp
(winged clamp with flat horizontal "jaws", for large premolars)
1 pc.
№ 2AD
Clamp
(fits on a premolar tooth and extends distally to provide rubber dam retraction, once placed the 2AD clamp allows comfortable access to the last tooth in the acrh)
1 pc.
№ 2AT
Clamp
("Tiger" clamp for canines and premolars of the upper and lower jaws with significant destruction of the crown part or a completely destroyed medial wall)
1 pc.
№ 2T
Clamp
("Tiger" clamp for canines and premolars of the upper and lower jaws, for teeth with minor destruction of the crown part)
1 pc.
№ 27N
Clamp
for premolars
1 pc.

Molar Clamps:

Symmetrical Design

№ W3
Clamp
(wingless clamp with flat horizontal "jaws", for small molars with pronounced contour height)
1 pc.
№ W7
Clamp
(wingless clamp with flat horizontal "jaws", for large molars with pronounced contour height)
1 pc.
№ 7
Clamp
(winged clamp with flat horizontal "jaws", for large molars with pronounced contour height)
1 pc.
№ W8A
Clamp
(wingless clamp with rigid angular "jaws", for large molars (festooned jaws for molars' roots))
1 pc.
№ 8
Clamp
(winged clamp with rigid angular "jaws", for large molars (festooned jaws for molars' roots))
1 pc.
№ 8A
Clamp
(winged clamp with rigid angular "jaws", for upper and lower molars with damaged coronal part)
1 pc.
№ 8AD
Clamp
(when working on mandibular molars provides enough distal retraction in the rubber dam to allow to place a tofflemire or saddle retainer (or similar))
1 pc.
№ 14
Clamp
(winged clamp with angular "jaws", for molars with damaged coronal part or mesial paries)
1 ps.
№ 14A
Clamp
(winged clamp with angular "jaws", for molars with damaged coronal part or mesial paries)
1 pc.
№ 26
Clamp
for upper and lower molars
1 pc.
№ W56
Clamp
(wingless clamp with rigid angular "jaws", for large lower molars (festooned jaws for molars' roots))
1 pc.
№ U67
Clamp
for second upper molars
1 pc.
№ 201
Clamp
(for upper and lower molars)
1 pc.
№ 202
Clamp
(for upper and lower molars)
1 pc.
№ S-G
Clamp
(fits on a molar tooth and extends distally to provide rubber dam retraction, once placed the 2AD clamp allows comfortable access to the last tooth in the acrh)
1 pc.

Left - Right Design

№ 12A
Clamp
(tiger clamp with serrated beak (left-sided), for second and third upper molars)
1 pc.
№ 13A
Clamp
(tiger clamp with serrated beak (right-sided), for second and third upper molars)
1 pc.
№ 22
Clamp
(for left-side premolars)
1 pc.
№ 23
Clamp
(for right-side premolars)
1 pc.
№ 24
Clamp
(left-sided clamp for upper and lower molars)
1 pc.
№ 25
Clamp
(right-sided clamp for upper and lower molars)
1 pc.
№ 138
Clamp
(left-sided clamp for third molars (with stiff spring and serrated beaks))
1 pc.
№ 139
Clamp
(right-sided clamp for third molars (with stiff spring and serrated beaks))
1 pc.
№ G-1
Clamp
(with large asymmetrical jaws for tongue retraction (left side))
1 pc.
№ G-2
Clamp
(with large asymmetrical jaws for tongue retraction (right side))
1 pc.

Deciduous Clamps:

Left - Right Design

№ 64
Clamp
(for 64 tooth)
1 pc.
№ 74
Clamp
(for 74 tooth)
1 pc.

№ 65
Clamp
(for 65 tooth)
1 pc.
№ 75
Clamp
(for 75 tooth)
1 pc.
№ 54
Clamp
(for 54 tooth)
1 pc.
№ 84
Clamp
(for 84 tooth)
1 pc.
№ 55
Clamp
(for 55 tooth)
1 pc.
№ 85
Clamp
(for 85 tooth)
1 pc.
№ P1
Clamp

(for 26 tooth)
1 pc.
№ P2
Clamp

(for 16 tooth)
1 pc.

Clamp Kits

№ 3.014
Clamps
10 pcs.:
№ B4, № 0, № 2, № 2А, № 7, № 8, № 9, № 12А, № 13А, № W56
№ 3.016
Deciduous Clamps
10 pcs.
№ 54, № 55, № 64, № 65, № 74, № 75, № 84, № 85, № Р-1, № Р-2
№ 3.017
Clamps
9 pcs.
№ 1, № 7, № 8, № 8А, № 9, № 14, № 201, № 202, № 212
For special request clamps can be designed in black color
WARNING!!!
When operating with clamp:
1) open the clamp for necessary width outside the mouth before placing it on a tooth;
2) avoid high-speed opening;
3) open the clamp for width not more than 1,5 mm exceeding tooth width
(undue force may cause clamp premature failure because of metal fatigue);
4) fix the clamp with floss to avoid clamp swallowing.

Cleaning and sterilization instructions:


1) Submerge instruments in cleaning agent solution with neutral pH for 20 min;
2) Rinse the instruments thoroughly with purified water for 3-5 min;
3) Perform standard moist heat / steam sterilization procedure following the sterilizer instructions.
WARNING!!!
1) Do not use cleaning agents with high percentage of chlorine and cleaners containing oxalic acid;
2) Do not keep instruments in liquid medium for more than 3 hours.

 

to the top

 